How mp/mp+ call spanning works, How mp/mp+ call spanning works -57 – Lucent Technologies 6000 User Manual

Page 189

Advertising
background image

Configuring Individual WAN Connections

Configuring MP, MP+ and BACP connections

MAX 6000/3000 Network Configuration Guide

4-57

When you have created or modified a nailed profile in RADIUS, you must reload the
information from the RADIUS server. To request a reload of all nailed profiles (permanent
connections) from the RADIUS server, select the command Sys > Sys Diag > Upd Rem Cfg.

Spanning multichannel calls across a stack of units

If you configure multiple MAX units to form a stack, the multiple channels of an MP or MP+
call can span the units in the stack, as shown in Figure 4-4.

Figure 4-4. A MAX stack for spanning MP or MP+ calls

Call spanning with a stack configuration can be effective when:

A MAX unit running MP+ asks for another telephone number, and has no available lines.

A rotary hunt group uses the same telephone number to access multiple units, making it
impossible to assume that the same unit that answered the original call answers a
subsequent call.

MP/MP+ call spanning is protocol independent and works with all protocols supported by the
unit.

Note:

Stacking requires any MP caller to use the MP endpoint discriminator. The same is true

of MP+. All Lucent products and most other products that support MP or MP+ use an endpoint
discriminator, but the specification for MP does not require it.

How MP/MP+ call spanning works

A stack is a group of MAX units that have the same stack information and are on the same
physical LAN. There is no master unit. The MAX units in the stack use a directed-broadcast
Ethernet packet to locate each other. Directed broadcast packets usually cannot cross a router,
so the units in a single stack must be on the same physical LAN. MAX units running in a stack
can generate fairly high levels of network traffic, which is another reason to keep them on the
same physical LAN.

Bundle ownership

Although MAX stacks do not have a master MAX unit, each bundle of channels in a MP/MP+
configuration has a bundle owner. The unit that answers the first call in the MP/MP+ bundle is
the bundle owner. If a bundle spans more than one unit in a stack, an exchange of information
flows between the units in the bundle.

MAX

MAX

MAX

WAN

MAX

Advertising