Settings in a radius profile, Examples of a circuit between uni interfaces, Using local profiles – Lucent Technologies 6000 User Manual

Page 274: Settings in a radius profile -26, Examples of a circuit between uni interfaces -26, Using local profiles -26

Advertising
background image

5-26

Preliminary January 4, 2001

MAX 6000/3000 Network Configuration Guide

Configuring Frame Relay
Configuring the MAX as a Frame Relay switch

Settings in a RADIUS profile

Following are the RADIUS attributes for configuring a Frame Relay circuit:

Examples of a circuit between UNI interfaces

Figure 5-10 shows a circuit configuration using UNI-DCE interfaces in the MAX.

Figure 5-10. Frame Relay circuit with UNI interfaces

Using local profiles

The following parameters on the MAX define the datalinks to the MAX and to the Pipeline
130 (P130-East):

Ethernet

Frame Relay

max

Name=max

Active=Yes

FR Type=DCE

FR Circuit

Circuit name (up to 16 characters). The other endpoint must
specify the same circuit name. If only one profile specifies a
circuit name, data received on the specified DLCI is dropped. If
more than two profiles specify the same circuit name, only two of
the profiles will be used to form a circuit.

Parameter

Specifies

Attribute

Value

Framed-Protocol (7)

Encapsulation protocol. Both endpoints of a circuit must specify
FR-CIR (263) encapsulation.

Ascend-FR-Profile-
Name (180)

Name of the Frame-Relay profile that defines the datalink.

Ascend-FR-DLCI (179)

A DLCI for this PVC endpoint. The MAX does not allow you to
enter duplicate DLCIs, except when they are carried by separate
physical links specified in different Frame-Relay profiles.

Ascend-FR-Circuit-
Name (156)

Circuit name (up to 16 characters). The other endpoint must
specify the same circuit name. If only one profile specifies a
circuit name, data received on the specified DLCI is dropped. If
more than two profiles specify the same circuit name, only two of
the profiles will be used to form a circuit.

DTE

DCE

DLCI 100

P130-West

DTE

DCE

DCE

DTE

DLCI 200

P130-East

MAX