Examples of a circuit between nni interfaces, Using local profiles, Examples of a circuit between nni interfaces -28 – Lucent Technologies 6000 User Manual

Page 276: Using local profiles -28

Advertising
background image

5-28

Preliminary January 4, 2001

MAX 6000/3000 Network Configuration Guide

Configuring Frame Relay
Configuring the MAX as a Frame Relay switch

The next set of profiles specifies the circuit between the two Frame Relay interfaces:

permconn-max-10 Password="ascend" , User-Service=Dialout-Framed-User

User-Name="max6",

Framed-Protocol=FR-CIR,

Ascend-Route-IP=Route-IP-No,

Ascend-FR-DLCI=100,

Ascend-FR-Profile-Name="max",

Ascend-FR-Circuit-Name="fr-cir1"

permconn-max-11 Password="ascend", User-Service=Dialout-Framed-User

User-Name="p130",

Framed-Protocol=FR-CIR,

Ascend-Route-IP=Route-IP-No,

Ascend-FR-DLCI=200,

Ascend-FR-Profile-Name="p130east",

Ascend-FR-Circuit-Name="fr-cir1"

Examples of a circuit between NNI interfaces

Figure 5-11 shows a circuit configuration that uses NNI interfaces.

Figure 5-11. Frame Relay circuit with NNI interfaces

Using local profiles

The following parameters on the MAX define the datalinks to the two switches labeled FR-
Asnd-A and FR-Asnd-B:

Ethernet

Frame Relay

fr-asnd-a

Name=fr-asnd-a

Active=Yes

FR Type=NNI

Nailed Grp=333

Ethernet

Frame Relay

fr-asnd-b

Name=fr-asnd-b

Active=Yes

FR Type=NNI

Nailed Grp=444

The next set of parameters specifies the circuit between the two Frame Relay interfaces:

FR-Asnd-B

FR-Asnd-A

DLCI 100

NNI

NNI

DLCI 200

NNI

NNI

Advertising
This manual is related to the following products: