Route ip and lan adrs, Example of an x.25 ip configuration, Figure 6-1 example of an x.25 ip connection -10 – Lucent Technologies 6000 User Manual

Page 296

Advertising
background image

6-10

MAX 6000/3000 Network Configuration Guide

Configuring X.25
Configuring X.25 IP connections

Route IP and LAN Adrs

The last two parameters to set values for are the Route IP parameter and the LAN Adrs
parameter.

The Ethernet > Connections > Connection profile > Route IP parameter specifies the routing of
IP data packets on the interface. IP routing must be enabled on both sides of the connection,
and the MAX unit must be configured with an IP address in the Ethernet profile. To establish
an inbound connection, IP routing must also be enabled in the Answer profile.

The Ethernet > Connections > Connection profile > IP Options > LAN Adrs parameter
specifies the IP address of remote-end host or router. The IP configuration for an X.25 IP
connection is identical to that of an IP routing connection that uses PPP encapsulation. You
must set the LAN Adrs parameter to the address of the remote unit. If you are using numbered
interfaces, you can also specify a local IF Adrs and a remote WAN Alias value. For details
about IP routing configurations, see Chapter 9, “Configuring IP Routing.”

For detailed information about each parameter, see the MAX Reference.

Example of an X.25 IP configuration

This section shows a sample configuration that enables two IP networks to connect through a
Public or Private Packet Switched Network, as shown in Figure 6-1.

Figure 6-1. Example of an X.25 IP connection

To configure this sample connection:

1

Open the Answer profile and enable X.25 IP encapsulation:

Ethernet

Answer

Encaps...

X25/IP=Yes

2

Open a Connection profile, name it, and activate the profile:

Ethernet

Connections

Connection profile

Station=newyork

Active=Yes

3

Enable IP routing and specify the IP address of the answering unit:

Route IP=Yes

Ip options...

LAN Adrs=10.65.212.226/24

4

Enable X.25/IP encapsulation and then open the Encaps Options subprofile.

5

Specify the name of the X.25 profile that carries this connection:

PSPDN

MAX

MAX

10.1.2.3/24

10.65.212.226/24

Advertising
This manual is related to the following products: