Specifications, Input specifications, Printing – Omega RD200 User Manual

Page 130

Advertising
background image

-126-

22. SPECIFICATIONS

1

Input Specifications

Number of measuring points: 1, 2, 3 and 4 points
Input signals: DC voltage (mV) …

±13.8, ±27.6, ±69.0, ±200

±500

DC voltage (V)…

±2, ±5, ±10, ±20, ±50 (Built-

in voltage divider for

±5 V or more)

DC current…Available by adding shunt

resistor (option)

Thermocouple…B, R, S, K, E, J, T, N,

NiMo-Ni, CR-AuFe, PtRh40-PtRh20

WRe5-WRe26, W-WRe26,

Platinel II, U, L

Resistance thermometer…Pt100 (1),

Pt100 (2), JPt100, Pt50, Pt-Co

Range: Program range number and printing range for each

channel with key operation. (See Section 8.2 for
range No. list)

Scale: Program minimum and maximum values with key

operation.
Programming range…-9999 to 99999
Decimal point … Program arbitrary

Measuring range: Refer to the list of range No. in Section

8-2.

Minimum printing range: Refer to the following table

DC

voltage

1/5 or higher than the measuring range.

Thermo-

couple

2/5 or higher than the measuring range when
converted into electromotive force.
(In the case of range Nos. with minus
measuring ranges, a temperature of 0°C or
higher is specified as the lower-limit
measuring value.)

Pt100

100°C span or more

Resistance
thermometer

Pt50

200°C span or more

Accuracy rating: Refer to item

6

(at reference operating

condition).

Temperature drift:

±0.01% full scale/°C (converted into

reference range)

Measuring cycle: About 100 msec (CH1 to CH4 )
Reference junction compensation: Inside (enable) or

external (disable) is selectable.

Reference junction compensation accuracy:

K, E, J, T, N and Platinel II…

±0.5°C or less

Other than the above*…

±0.1°C or less

*Except PtRh40-PtRh20

Input resolution: Approx. 1/56000 (converted into reference

range)

Burnout:

Effective input… Thermocouple, resistance
thermometer
Programming range …Selection from up-scale,
down-scale or disable for each channel

Allowable signal source resistance:

DC voltage inputs, thermocouple inputs

…1k

Ω or less*

Resistance thermometer inputs

…10Ω or less

* Without burnout

Input resistance: Thermocouple input …About 8M

DC voltage inputs (range of

±2 V or less)

…About 8M

DC voltage inputs (range of

±5 V or less)

…About 1M


Maximum input voltage

DC voltage

inputs,

thermocouple

±10 V DC or less (range of ±2 V or less)

±60 V DC or less (range of ±5 V or less)

Resistance

thermometer

±6 V DC or less

Input correction: Shift programming for each channel
Input filter: Program primary delay filter

1 to 10 sec. and “0” (none) for each channel.

Maximum common mode voltage: 30VAC
Common mode rejection ratio: 140 dB or more (50/60 Hz)
Series mode rejection ratio: 50 dB or more (50/60 Hz)
Terminal board: Detachable and removable for wiring

2

Printing

Printing accuracy: Measuring accuracy +

±.0.3% of printing

range (under the reference operation

condition)

Printing dead and: 0.2% of printing range

Printing system:

Trace printing… Disposable cartridge pen

Digital data printing …. Plotter pen

Step response: RD200 … 1 sec. or less (90% response)

RD2800 … 1.5 sec. or less (90% response)

Print color: Trace printing …. 1

st

pen (Red), 2

nd

pen (Green),

3

rd

pen (Blue), 4

th

pen (Brown)

Digital data printing … Purple

<<Digital printing>>
cPeriodic
data printing

: Printing of time, channel No., measured

values and engineering unit with
programmed interval

dDigital data
printing

: Printing of time, channel No., measured

values and engineering unit with trace
printing on demand

eYear, Month,

day, time, time
line

: Printing of year, month, day and time when

turning on the power. Printing time line and
time every on the hour. Printing year, moth
and day at 00:00 and every specific interval

fChannel No.,

scale, tag ゙

: Printing of scale, channel No. and tag (only if

they are programmed) with every specific
interval

gChart speed : Printing of chart speed with every specific

interval

hAlarm

Activation/
Reset

: Printing of time, channel No., alarm type and

alarm level when an alarm activates. Printing
time, channel No. and alarm level when the
alarm is reset. Memory volume is max. 48
data

iProgramming

change mark

: Marking when changed parameters are

stored

jPOC mark

: Marking when time-axis synchronization is

programmed

kList printing

: Printing of parameters (list 1 or 2) on demand

List 1: Chart speed, range/printing range,

scale, subtract printing, periodic data
printing, printing format and alarm

List 2: Chart speed (3 speeds), alarm output,

time-axis synchronization, remote
contacts and math expression

List 3: All parameters (List 1 + List 2)