Other programming, 7periodic data printing – Omega RD200 User Manual

Page 72

Advertising
background image

-68-

11. OTHER PROGRAMMING

11.7Periodic Data Printing

This programming is for digital printing (data printing) at fixed intervals. The printing overlaps with trace printing.

Press and simultaneously to display [Periodic data printing] screen. As the default is no

programming of parameters for the periodic data printing, the periodic data printing is not executed.

1

Periodic Data Printing

(1) Program start time and interval time.
(2) The printing format with a chart speed of 99 mm/h or

slower is shown below.

<Example> 18:30 1: 225

°C 2: 316°C

2

Programming Mode







3

Programming Flow Chart

<Example> Periodic data printing with a start time of 12:00 and

interval time of 4 hours

Operation screen

[Check]


[To be ready for programming]

[Programming interval time]

→ →




[Programming start time]

→ →


  

Error message appears?

Stored


It depends on the chart speed and
number of printing lines.

180 x number of printing lines*

T (Min.) ≧

Chart speed *1

(Note) However, T is 5 minutes or more.
*1: When 3-speed is programmed by

the remote contacts (option), the
slowest speed is applied.

*2: Depending on the chart speed

and number of channels.

Chart speed

CH1 CH2 CH3

CH4

99 mm/h or slower

1 line

2 lines

100 mm/h or faster

1 line 2 lines 3 lines 4 lines



Press and
simultaneously to clear and carry out
[store].


The programmed values in the [Periodic
data printing] are cleared and the
periodic data printing stops. Reprogram
it if necessary.


In case electric power failure occurs and
the power is turned on in the following

day, reprogramming is required if

24

T

is

not an integer. (T: Interval time)

Minute

Hour

Interval time

Start time

(Fixed)

(Fixed)

Time

An example of periodic data printing

(RD200)

Cursor

Interval time

Start time

YES

NO

Shortest time of interval time (T)

Remarks 1

From power off to on

<Chart paper speed: 100 mm/h or faster>

SHIFT

5

DATA I

DISP

SHIFT

5

DATA I

SET

END

0

CLEAR

0

CLEAR

0

CLEAR

4

SCALE

2

TAG

0

CLEAR

0

CLEAR

1

CHART

ENTRY

SHIFT

0

CLEAR

Hour

Minute

Any key other
than

SHIFT

To program periodic data
printing to “none”

Remarks 2

When the chart speed is changed;

Remarks 3

Remarks 4

Advertising