Printing format – Omega RD200 User Manual

Page 96

Advertising
background image

-92-

14. PRINTING FORMAT

14.1

Programming Automatic Range-Shift Printing


This programming display only appears for the
printing format (option). This programming is to
change the trace printing range automatically.

1

Automatic Range-shift

The automatic range-shift function changes
the trace printing range up to 5 stages
according to the measured values.

(1) This programming can be applied to each

channel.

(2)

The total printing range can be
programmed optionally irrespective of the
programmed range in the [Range/Printing
range].

(3) For each range, refer to the minimum

printing range in section 22.1 (Input
Specifications). The printing may be
dispersed if each range is programmed to
be less than the minimum printing range.

(4) The range shifting is executed when the

measured value exceeds approx. 0.5 mm
from the minimum (zero) or the maximum
(span) range.


2

Programming Mode

1) Screen 1 (Printing format check)

    




Dots appear at the selected format.
By pressing , the dots disappear and the
cursor appears instead.

2) Screen 2 (Programming channel)






By selecting automatic range-shift (), the cursor
appears at the channel programming position.


3) Screen 3 (Zero programming at No.1 range)

   



(1) The default programmed value is the minimum

value in the [Range/Printing range]. This
programming can be changed as required.

(2) When all programming are completed, return to

the above display and execute [Storing].


4) Screen 4 (Span programming at No. 1 to 5

ranges)

    



(1)

When the programming a span, the range
number advances. Program the span up to the
required range number.

(2) After pressing up to range No.5, press

again to return to Display 3.

Mark is the programming point and No. (1) to (5) shows

the order of programming. By pressing when the

programming ends, the screen moves to the next

programming screen. As No. 5 is not used in this example,

only press .

Printing range

for 1st range

-100

400

(1)

(2)

Printing range

for 2nd range

(3)

(400)

600

Printing range

for 3rd range

(4)

(600)

800

Printing range

for 4th range

(5)

(800)

1200

-

100

400

600 800 1200

1st range

(R1)

4th range

(R4)

2nd

range

(R2)

3rd

range

(R3)

-200

1370

Measuring value

<Example> Automatic range-shift programming

<Range No. 23 (K thermocouple)>

Standard

Automatic

range-shift

Zone

Compressed/expanded

Programming value

(Max. 5 digits by left-justify)

Range No.

Span

Total printing

range

ENTRY

ENTRY

SET

END

ENTRY

ENTRY

Automatic range selection

Channel

Cursor

Programming value

(Max. 5 digits by left-justify)

Range No.

Zero