Other programming, 5 alarm – Omega RD200 User Manual

Page 70

Advertising
background image

-66-

11.OTHER PROGRAMMING

11.5 Alarm

2) With alarm output (option)

Operation screen

[Output check]


 

[Programming check]

  

[To be ready for programming]

 

[Programming alarm point]

  

[Selecting alarm type]

   

[Programming relay No.]

   

[Programming alarm value]

   

[Only rate-of-change alarm]


   

[Only differential alarm]


   

Temporarily stored

Programming other alarm points?



Stored



Follow the [Programming alarm point]
procedure and select the alarm point

to be deleted with .

Clear it by pressing and

simultaneously and perform
[temporarily stored] and [stored]
operation.


The relay Nos. in alarm output are
displayed. This will be blank unless all
of the relays are operated.


By pressing , the level
advances from 1 to 4 and the
channel advances to the next
channel and then the level of the next
channel advances. Press for
reverse operation.


1. Channel can be selected also with
or .
2. Channel advances by pressing

Then “FaiL” and “C.End” appear. If
these functions are selected,
program relay Nos. only.



This is for specifying terminal Nos. for
alarm output.
The relay No. for AH is displayed with
2 digits such as “00”. See Section
12.2.When programming “1” to “9”,
two entering methods of 1 to 9 or
01 to 09 are available. ( : space)


Programming range is 1 to 20.


Reference channel to be compared is
programmed in 1 to 4. (The
differential alarm cannot be selected
in a 1-pen type recorder because no
channel to be compared is existed.)


Store the [temporarily stored]
programmed values into the memory.
(A programming change mark is
printed.)

Numeric
keys

Numeric
keys

Cursor

Channel

Relay No.

Alarm value

Level

Alarm type

Measuring count

YES

NO

Channel to be compared

Relay No.

DISP

SHIFT

8

ALARM

ENTRY

SET

END

%

/

°F

°F

°F

ENTRY

SHIFT

SET

END

Storing

Reference 7

To delete alarm point

/

%

Other alarm point check

Reference 2

Programming alarm point

Reference 3

Cursor appears only for

rate-of-change alarm.

Reference 5

Cursor appears only for

differential alarm.

Reference 6

Output check

Reference 1

Relay No.

Reference 4

Numeric
keys

Numeric
keys

When an error
appears
press any key other
than

SHIFT

Ref. 7

Ref. 6

Ref. 5

Ref. 4

Ref. 3

Ref. 2

Ref. 1

1

CHART

4

SCALE

to

/

SHIFT

0

CLEAR

/

%

/

Advertising
This manual is related to the following products: