12. ALARM OUTPUT

12.1 Alarm Output Programming Items


This explanation is only for the alarm output (option). The alarm output programming is necessary after
programming the “alarm”.

1

Programming Items for Alarm Output

1) Relay No.

Setting of the relay No. where the alarm information (activation/reset) of each alarm point is
to be output. Set them to each alarm point.

2) Output wiring

Setting to AND or OR for each relay No.. When one relay is used by multiple alarm points,
you can select AND or OR for the output wiring.

(1) Relay coil phase: Setting whether N and O terminals are shorted (Energized) or opened

(Non-energized) when an alarm activates.

(2) Relay output latch: Setting whether the alarm status is to be continued until is
pressed (Hold) even if the alarm becomes reset condition, or it is reset (Not hold) at the

same time as resetting of the alarm.

3) Output mode

(3) Alarm display

*

latch: Setting whether the alarm display is kept displayed until is

pressed (Hold) even if the alarm becomes reset condition or turned off (Not hold) at the

same time as resetting of the alarm.

* Alarm display: ALARM status lamp

2

Details of Programming Items

1) Relay No. and default values

Alarm *

Alarm point

Alarm type

Relay No.

Level 1

Level 2

Level 3

CH 1

Level 4

Level 1

Level 2

Level 3

CH 2

2 to 4-pen
types only

Level 4

Level 1

Level 2

Level 3

CH 3

3 and 4-pen

types only

Level 4

Level 1

Level 2

Level 3

CH 4

4-pen type

only

Level 4

FAiL

C. End

*This is the “Alarm” programming. The relay No. is

fixed at 0 in the standard specifications (AH is fixed
at 00). 1 to n (Note) should be set only when alarm
output (option) is added. (0 means no output.)

(Note) n: 6 or 12 depending on the number of output

points.
RD200: 6 only

2) AND/OR, output mode and default values

Output Mode

Relay

No.

AND/

OR

Relay coil

phase

Relay

output

latch

Alarm

display

latch

RLy1

or

RLy2

or

RLy3

or

RLy4

or

RLy5

or

RLy6

or

RLy7

or

RLy8

or

RLy9

or

RLy10

or

RLy11

or

RLy12

or

Energized

Common

to all

relays

Not hold

Common

to all

relays

Not hold

Common

to all

displays

* RD200: Relay No. is 1 to 6.

RD2800: it is variable depending on the number
of output points (Rel;ay No. is 1 to 12 for
12-point outputs.).