-27-

Bargraph

CH 1
CH 2
CH 3

Measured value

Status

Ch 1

Ch 2

Ch 3

Chart speed

6.

BASIC OPERATION

6.1 Power Supply and Operation

1

Power Supply On/Off

Your recorder is not provided with a power switch.
Prepare an external power switch for turning on or
off its power supply.

2

Initial Operation

By turning on the power supply, 1) year, month and
day are displayed. After initialization, 2) year, month,
day and time are printed (Printing when the power
is turned on) and 3) the normal operation starts.

3

Operation

1) Operation screen

(1) Measured values for all channels (CH 1 to 4: depending on the numbers of input points) are digitally
displayed.
(2) Measured values for all channels (CH 1 to 4: depending on the numbers of input points) are displayed by
bargraphs.
(3) A corresponding status lamp lights. The default is RECORD ON.







(Note) The above example is for RD200. It is the same for RD2800.

2) Chart paper feeding

The chart paper is fed at the programmed chart paper
speed. (The default speed is 20 mm/h for RD200 and
25 mm/h for RD2800.)

3) Printing

(1) Trace printing

Measured values are traced by a cartridge pen.

<Ink colors> CH 1: Red, CH 2: Green, CH 3: Blue, CH 4: Brown

(2) Digital data printing
a. Fixed-time printing

The following data is printed at preset time intervals.
•Time line •Time •Year/Month/Day •Chart speed
•Scale •Engineering unit •Tag

b. Other printings

The following printings are executed according to programming and operation.
•Periodic data printing •Digital data printing •List 1, 2 and 3 •Programming change mark
•Alarm activation/reset •Message •Operation printing line and No. •Time axis synchronization mark

Overcurrent

protective device

(250V 3A)

Power and protective
conductor terminals

To protective conductor of
power supply facility

Power supply source

Power switch

L

N

Power switch installation

Example of operation screen (3-pen type)

Trace printing and fixed-time printing

(Note) The above example is for RD200.