EFP9800 ESC/POS Commands

3255 4073– 002

6– 31

The command is ignored if the value of v, b, f, or h is out of range. Any following
data is processed as normal data.

Hexadecimal Decimal

ASCII

1B 26 v b f [h u1, l1, u2, l2 .
. . uh, lh]*

27 38 v b f [h u1, l1, u2, l2
. . . uh, lh]*

ESC & v b f [h u1, l1, u2, l2 . . .
uh, lh]*

*The data in [ ] is repeated f - b + 1 times, once for each character to be
defined.

Value

Range (in decimal)

Description

v

2

Fixed to 2

b

32 - 126

Beginning character code in range. (To define only 1 character, make
b = f) b must be

f.

f

32 - 126

Final character code. (To define only 1 character,
make b = f) b must be

f.