MICR Commands and Parsing

11–2

3255

4073–002

Reread MICR Data

Resends the unparsed MICR data (as if the parsing has not been defined) from
the previous MICR sequence.

Hexadecimal Decimal

ASCII

1B 77 52

27 119 80

ESC w P

Define Parsing Format, Do Not Save Permanently

Defines, but does not save parsing format. See “Parsing Parameter String
Options” on the next page. Send this command at the start of day or use in the
setup application. If no parameters are selected, parsing is not performed.

Hexadecimal Decimal

ASCII

1B 77 70
parameters

27 119 112
parameters

ESC w p
parameters

MICR Parsing

This section describes the MICR parsing in more detail and includes several
examples of useful parsing variations. It also describes how to create a parsing
format and how to create and maintain an exception table.

If you would like a copy of a software utility that performs these functions
rather than developing your own program using the command codes described
in this section, please contact Unisys. The software utility can be used as
provided or can be incorporated into your own application.

Advertising