PROGRAM STEPS

MILLPWR

®

Operation Manual

Frame

A circular frame is determined by its center point and radius. The direction will
determine if you are climb cutting or conventional cutting. The tool offset will deter-
mine if you are cutting an inside or outside frame.

To program a circular frame:

Press the

CIRCLE

key.

Press the

FRAME

softkey.

Enter the X- and Y-axes coordinates for the center
point.

Enter the depth.

Enter the radius.

For the direction, press the

CW

softkey for

clockwise or the

CCW

softkey for a counter-clock-

wise direction.

5-23

INSIDE

FRAME

OUTSIDE

FRAME