ACU-RITE MILLPWR 2 Axes User Manual

Page 26

Advertising
background image

DRO

MILLPWR

®

Operation Manual

2-9

Position the tool so that it is near, but not touching,
the left side of the part.

Lower the tip of the tool so that it falls below
the top surface of the part.

Move the table along the X-axis slowly, while
spinning the tool by hand. Pay close attention as
the tool approaches the part— a subtle bump will be
felt when they come into contact.
Stop the table at the moment the tool touches the part.

Using the keypad, enter the radius of the tool (the distance from the
center of the tool to the edge of the part). Be sure to specify if it’s
a negative value.

Note:

For this example, specify a negative value, because the tool's
center is on the negative side of datum
(refer to Axis Conventions).

Press the

ENTER

key.

Now set datum for the Y-axis using the same procedure:

Position the tool so that it is near, but not touching,
the front face of the part. The tip of the tool should
fall below the top surface of the part.

Move the table along the Y-axis, slowly spinning the
tool by hand. Pay close attention as the tool
approaches the part— A subtle bump will be felt when they make contact with
each other. Stop the table at the moment the tool touches the part.

Using the keypad, enter the radius of the tool into the"Y" field
(be sure to specify if it is a negative value).

Press the

ENTER

key.

Use the MOVE
TABLE softkey
to help with
long table
moves.

Advertising