Setup, Operation manual – ACU-RITE MILLPWR 2 Axes User Manual

Page 192

Advertising
background image

SETUP

MILLPWR

®

Operation Manual

7-23

Spindle Control

If you are using a milling machine that has an electronic variable-speed spindle,

MILLPWR

will soon be able to control the spindle for you.

With the spindle control enabled,

MILLPWR

will apply the direction and speed parameters

you enter into the "Set Tool” step of a program. Depending on the spindle's motor, you may
be able to control the spindle's speed and direction, or just the direction.

If the spindle control is disabled, the settings you program in "Set Tool" will be displayed
in an Operator Intervention Message (OIM) when you run the program. You will be prompt-
ed to set the speed and direction manually.

Error Log

MILLPWR

includes a built-in error log that will record system assertion failures. If an assertion

failure is detected,

MILLPWR

will automatically record the date, along with a brief description

of the failure.

Messages can be cleared by pressing the

CLEAR

key, then pressing

YES

to proceed or

NO

to

cancel. It’s best to let messages accumulate to establish a history.

To save these records for future reference, place a floppy disk into the disk drive and press the

SAVE FLOPPY

softkey.

Advertising