PROGRAMMING

MILLPWR

®

Operation Manual

3-16

Machining to Zero

MILLPWR

is factory preset in a distance to go display view. Any dimension programmed

will be "preset" into the readout display. Every move will begin at the preset value and end
at zero.

If a depth has been programmed, a prompt will instruct you to position the Z-axis.

MILLP-

WR

will preset the value into the readout's Z-axis. The DRO screen will appear, along with

the following prompt:

Position the Z-axis until the absolute display is 0.0000.

To set up

MILLPWR

to the incremental travel display view refer to System Setup. In this

view, every move will begin at zero and end at the programmed position. For example, a
programmed depth of -0.5000, will display, the following prompt:

Move the Z-axis until the absolute display shows the target position (e.g., -0.5000”).