TROUBLESHOOTING GUIDE

MILLPWR

®

Operation Manual

9-11

No response from PC
(cont'd)

Time-out error

The selected COM port
is disabled.

Loose serial cable

Change the PC's COM
port setting and connect
the serial cable into the
appropriate port;

-OR-

Exit the remote storage
program on the PC, then
refer to the PC’s operation
manual for instructions on
how to enable a COM
port.

Check that the serial cable
is properly connected to

MILLPWR

and to the PC.

The PC’s COM port
setting is different from
the COM port that the ser-
ial cable is connected to.

If the COM port setting
(1 or 2) on the PC screen
does not correlate with the
COM port that the serial
cable is connected to:

Change the PC’s COM
port setting;

-OR-

Disconnect the cable from
the COM port that it is
connected to and connect it
to a different COM port.

Symptom

Recommended
Corrective Action

Probable Cause