Error Compensation

MILLPWR

is able to automatically calculate and compensate for machine

tool wear.

If you know the error compensation value in parts per million (PPM), you
can enter it directly. Otherwise, use the following procedure to determine
the value for each axis:

Note:

You can only perform error compensation for one axis at a time.

• Set up a standard of known length (e.g., a gage block), by indicat-

ing it in along the axis to be measured. Check that the standard is
straight and parallel with the axis you are working with.

• Enter the length of the standard.

If you need to touch each end of the standard using opposite
edges of the electronic edge finder or mechanical indicator, be
sure to include its diameter when entering the length of the
standard. (Refer to the graphic below.)

• Touch one end of the standard and press the

FIRST POINT

softkey.

If you are using an electronic edge finder, you won’t have to

press the first point softkey.

• Touch the opposite end of the standard and press the

SECOND

POINT

softkey. If you are using an electronic edge finder, you

won’t have to press the second point softkey.

MILLPWR

will determine and automatically enter the correct

compensation factor in parts per million.

• Continue with Setup or press the

USE NEW SETTINGS

softkey.

Before perform-
ing linear error,
compensation,
you need to
ensure that the
machine is
properly adjust-
ed. Refer to the
manufacturers’
instructions.

Check between
the first and
second points
several times—
note the error
value to ensure
repeatability.

Advertising