Setup, Operation manual – ACU-RITE MILLPWR 2 Axes User Manual

Page 199

Advertising
background image

SETUP

MILLPWR

®

Operation Manual

7-30

The signal test shows when an axis was last tuned and whether or not the digital-to-analog
converter is emitting an analog signal. When the test is complete, either “Pass” or “Fail”
will appear in the “Signal Test Result” field. If a failure is reported, check the message bar
prompt for details.

Signal Test

To enable or disable the motor assembly monitor:

From the Diagnostics screen, highlight "Motor Assembly Monitor" and press

ENTER

.

Press either the

ENABLED

or

DISABLED

softkey. (If the

ENABLED

softkey is selected,

the motor assembly monitor display will appear on the DRO screen.)

Press the

USE

key.

Continue with Diagnostics or press the

USE NEW SETTINGS

softkey.

To display the signal test:

From the Diagnostics screen, highlight "Signal Test"
and press

ENTER

.

Press the softkey for the appropriate axis.

Press the

EXIT TEST

softkey to close the “Signal

Test” screen.

Continue with Diagnostics or press the

USE NEW

SETTINGS

softkey