PROGRAM STEPS

MILLPWR

®

Operation Manual

5-48

Press the

MORE STEPS

softkey again.

Press the

CHAMFER

softkey.

MILLPWR

will automatically fill in the "From" and

“To” fields in “Steps” for you. (Press the

CLOSE

CONTOUR

softkey if you want to chamfer the end of

a contour with the beginning.)

Enter the distance from the common point of both
lines. ("Length 1" refers to the line listed in the
"From" field; "Length 2" refers to the line listed in
the "To" field.) If you plan to use an angle, enter
only one length.

If you entered one length above, highlight the
"Angle" field and enter the chamfer's angle from the
X-axis; otherwise, leave it blank.

Adjust the feed rate, if necessary.

Press the

USE

key.