SETUP

MILLPWR

®

Operation Manual

7-22

Serial Port

You can connect

MILLPWR

to a PC via the serial port (located on the rear of the operator

console). The serial port allows you to store part programs on a PC.

To activate the serial port:

From Installation Setup, highlight “Serial Port”
and press

ENTER

.

Press the

REMOTE STORAGE

softkey to change

the “Function” setting from “Off” to “Remote
Storage.”

Highlight “Baud Rate.”

Define the Baud rate by pressing the

LOWER

or

HIGHER

softkeys. The Baud rate you select must

match the PC’s Baud rate.

Highlight “Handshaking.”(The handshaking feature verifies that

MILLPWR

and the

PC are communicating properly during file transfers.)

Press the

ENABLED

softkey.

Press the

USE

key.

Continue with Setup or press the

USE NEW SETTINGS

softkey.