DEMONSTRATION

MILLPWR

®

Operation Manual

4-8

Next, enter the line that starts at the bottom of the arc.

Press the

LINE

key and enter the following

information:

TO:

X2 = -3.0 ABS

Y2 = -1.5 ABS

Press the

USE

key.

Press the

LINE

key to add another line. Now

enter the following information:

TO:

X2 = -3.0 ABS

Y2 = -0.838 ABS

Press the

USE

key.