Setup – ACU-RITE MILLPWR 2 Axes User Manual
Page 189
SETUP
MILLPWR
®
Operation Manual
7-20
To set your travel limits:
•
From Installation Setup, highlight "Travel Limits" and
press
ENTER
. The “X-axis Travel” field should be high-
lighted.
•
Move the table to the position where you want the
right table travel limit set.
•
Press the
SET RIGHT LIMIT
softkey.
•
Move the table to the position where you want the left table
travel limit set.
•
Press the
SET LEFT LIMIT
softkey.
Note:
The X-axis travel field will update to show you the
maximum allowable traveling distance between the left
and right table travel limits.
•
Now highlight the "Y-axis Travel" field.
•
Move the table away from you until you have reached the
position where you want the inside table travel limit set.
•
Press the
SET INSIDE LIMIT
softkey.
•
Move the table towards you until you have reached the position where you want
the outside table travel limit set.
Use the handles
or the MOVE
TABLE feature
to position the
table.
If you use
MOVE TABLE,
keep in mind
that the table
travel limits are
not activated.
Travel Limits
Travel limits define how far you will allow the table to move along the X- and Y-axes.
Note: You must find home before you can establish the travel limits.