Setup, Operation manual – ACU-RITE MILLPWR 2 Axes User Manual

Page 194

Advertising
background image

SETUP

MILLPWR

®

Operation Manual

7-25

Automatically Tuning the Servo in Console Mode

1. Make sure the axis you are tuning is roughly in the middle of its travel

(They will be moving approximately two (2) inches in each direction.)

Note to Installer: No RS-232 cable should not be connected to any axis. Setting value

tables could become contaminated.

2. Power up the

MILLPWR

console, make sure the E-Stop button is out, and

home the axes as you would normally.

3. Press the “Setup” key.

4. Arrow down to highlight “Installation Setup” and press

ENTER

.

5. When prompted type in the required passcode and press

ENTER

.

6. Arrow down to “Servo Tuning” and press

ENTER

.

7. Select the axis you want to tune by pressing the appropriate soft key.

8. The prompt bar should indicate you are in Console Mode.

9. Press the

AUTO TUNING

soft key, then press the

BALANCE TEST

soft key.

10. The console will begin adjusting the balance values until it finds the value that keeps the

axis as motionless as possible.

11. When the Auto Tuning process is completed, the prompt bar will read “Test Completed.” Now pro-

ceed with the Gain Test.

12. Make sure the axis you are tuning is roughly in the middle of its travel. Press the

GAIN TEST

soft

key.

Do not touch the table during the balance test.