4-17

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

Command/response table for SIS commands (continued)

N

X@

= Output number

01 – (maximum number of outputs for your model)

X$

= Input number

01 – (maximum number of inputs for your model)

X(

= Global preset #

01 – 64

X1)

= Room # (for room presets)

01 – 10 (Each can have up to 10 presets (

X1@

s) assigned.)

X1!

= Name

12 alphanumeric characters maximum for presets, inputs, and outputs

11 characters maximum for room names

X1@

= Room preset #

01 – 10

X1&

= Group # (for I/O grouping) 1 – 4 (0 = no group)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

I/O Grouping (continued)

Read input grouping

E

I

}

X1&

1

X1&

2

X1&

3

...

X1&

n

]

Each

X1&

entry is the group

number assigned to an input
position, starting from input 1.
n

is the highest-numbered

input for this model.

Example:
MAV Plus 4848

E

I

}

See below.

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08 09 10 11 12

1 1 1 3 3 0 0 0 0 4 4 4 4 1 1

13 14 15

Input 9 not grouped

1 2 2 3 3 3 3

35

34

36 37 38 39 40 41

2 1 2 2 3 3 3

42 43 44 45 46 47 48

Input 48 in group 3

Read output grouping

E

O

}

X1&

1

X1&

2

X1&

3

...

X1&

n

]

Each

X1&

entry is the group

number assigned to an output
position, starting from
output 1. n is the highest-
numbered output for this
model.

Names

Write global preset name

EX(,X1!

NG

}

Nmg

X(,X1!]

Example:

E

1,Security 1NG

}

Nmg01

,

Security 1

]

Name global preset 1
“Security 1”.

Read global preset name

EX(

NG

}

X1!]

Example:

E

2NG

}

Security 2

]

Global preset 2 is named
“Security 2”.

Write room name

EX1),X1!

NR

}

Nmr

X1),X1!]

Example:

E

1

,

Classrm 1NR

}

Nmr01

,

Classrm 1

]

Name room 1 “Classrm 1”.

Read room name

EX1)

NR

}

X1!]

Write room preset name

EX1)

*

X1@,X1!

NP

}

Nmp

X1)

*

X1@,X1!]

Example:

E

1*3

,

Podium_DVDNP

}

Nmp01*3

,

Podium_DVD

]

Name room1, preset 3
“Podium_DVD”.

Read room preset name

EX1),X1@

NP

}

X1!]

N

• If a preset is unassigned, the

X1!

displays

[unassigned].

If a global preset is saved, but not yet named, the default name is Preset

X(

.

If a room preset is saved, but not yet named, the default name is Rm

X1)

Prst

X1@

.

Write input name

EX$,X1!

NI

}

Nmi

X$,X1!]

Example:

E

1

,

Podium camNI

}

Nmi01

,

Podium cam

]

Name input 1 “Podium cam”.

Read input name

EX$

NI

}

X1&]

Write output name

EX@,X1!

NO

}

Nmo

X@,X1!]

Example:

E

1,Main PJ1NO

}

Nmo01,Main PJ1

]

Name output 1 “Main PJ1”.

Read output name

EX@

NO

}

X1!]