Pinging to determine web ip address – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 163

Advertising
background image

A-3

CrossPoint 450 Plus and MAV Plus Switchers • Ethernet Connection

4

.

At the DOS prompt, type

ping {IP address} and then press

Enter

. The

computer returns a display similar to as shown below.

The line Pinging ... reports the actual numeric IP address, regardless of

whether you entered the actual numeric IP address or an alias name.

C:\>ping 192.168.254.254

Pinging 192.168.254.254 with 32 bytes of data:

Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128

Ping statistics for 192.168.254.254:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms

Pinging to determine the Web IP address

The Ping utility has a modifier, -a, that directs the command to return the Web

address rather than the numeric IP address.
At the DOS prompt, type

ping -a {IP address} and then press

Enter

. The

computer’s return display is similar to the Ping response shown in the figure

above, except that when you specify the -a modifier, the line Pinging mail... reports

the web IP address rather than the numeric IP address, regardless of whether you

entered the actual numeric IP address or an alias name.

Configuring the matrix switcher BME for network use via the ARP command

The ARP (address resolution protocol) command tells your computer to associate

the matrix switcher BME’s MAC (media access control) address with the assigned

IP address. You must then use the ping utility to access the controller, at which

point the controller’s IP address is reconfigured.
Use ARP to configure the IP address as follows:

1.

Obtain a valid IP address for the matrix switcher BME from your network

administrator.

2.

Obtain the BME’s MAC address (UID #) from the label on its rear panel. The

MAC address should have this format: 00-05-A6-xx-xx-xx.

3.

If the matrix switcher BME has never been configured and is still set for

factory defaults, proceed to step 4. If not, perform a Mode 4 system reset

and then proceed to step 4. For detailed information on reset modes, see

Performing soft system resets (reset modes 3, 4, and 5)” in chapter 3,

“Operation”.

N

The matrix switcher BME must be configured with the factory default IP

address (192.168.254.254) before the ARP command is executed, as described on
the next page.