CrossPoint 450 Plus and MAV Plus Switchers • Ethernet Connection

A-2

Ethernet Connection

Ethernet Link

The rear panel Ethernet connector on the CrossPoint 450 Plus and

MAV Plus switcher BMEs can be connected to an Ethernet LAN or

WAN. This connection makes SIS control of the switcher possible using

a computer connected to the same LAN. Although for normal system control, the

connection is to BME 0, you can connect to and communicate with any BME (for

example, you connect to other BMEs to perform a firmware upgrade).

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover

cable and must be properly terminated for your application (figure A-1).

Crossover cable — Direct connection between the computer and switcher

BME (usually BME 0)

Patch (straight-through) cable — Connection of a switcher BME (usually

BME 0) to an Ethernet LAN

A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.

A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Crossover Cable

Straight-through Cable

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

End 1

End 2

End 1

End 2

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

Pin

1

2
3
4
5
6
7
8

Wire color

White-orange

White-green

Blue

White-blue

White-brown

Brown

Wire color

T568B

T568B

White-orange

Orange

Orange

White-green

Blue

White-blue
Green

Green

White-brown

Brown

Figure A-1 — RJ-45 connector pinout tables

Default IP address

To access the matrix switcher BME via the LAN port, you need the switcher’s IP

address. If the address has been changed to an address comprised of words and

characters, you can determine the actual numeric IP address using the Ping utility.

If the address has not been changed, the factory-specified default is 192.168.254.254.
Ping can also be used to test the LAN port of any CrossPoint 450 Plus or MAV Plus

switcher BME.

Pinging to determine the Extron IP address

The Ping utility is available at the DOS prompt. Ping tests the Ethernet interface

between the computer and a switcher BME (usually BME 0). Ping can also be used

to determine the actual numeric IP address from an alias and to determine the web

address.
Ping the switcher as follows:

1

.

On the Windows task bar, click on Start > Run.

2

.

At the Open prompt, type

command.

3

.

Click the OK button.