3-37

CrossPoint 450 Plus and MAV Plus Switchers • Operation

4

.

Change the input level

: Press and release the View (

<

) button once to

decrease the input audio level by 0.5 dB.

Press and release the View (

<

) button several more times to decrease

the input audio level by 0.5 dB per button press. Note the output

button indications that change each time the View (

<

) button is pressed.

The figure below shows the result of pressing the View (

<

) button a total of

17 times. Note that the level is now displayed in red to indicate a negative

(attenuation) level.

VIEW

17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8

25

9

26

10

27

11

O
U

Press the View button to decrease the input
audio level by 0.5 dB per push of the button.

The output buttons display the

selected input's audio level and

polarity (gain or attenuation).

Each output button indicates 0.5 dB
when flashing and 1 dB when lit.
When the buttons are lit

green, they

indicate a

gain (+) audio level.

When the output buttons are lit

red,

they indicate an

attenuation (-) level.

In this example, the output buttons

display an audio attenuation level of

-1 dB.

N

You can press and hold the Esc (

>

) or View (

<

) button to ramp the level up or

down by 3 dB per second to the high or low limit.

5

.

Exit

Audio mode:

Press and release the Audio button.

I / O

RGBHV AUDIO

The Audio button stops
blinking and lights.

Press the Audio button
to exit audio mode.

All

input buttons and output buttons

return to unlit or background illumination.

The RGBHV or Video
button lights

green.

Advertising