Performing soft system resets (reset modes 3, 4, and 5)

Perform a soft reset of the switcher as follows:

1

.

Use an Extron Tweeker or other small screwdriver to press and hold the rear

panel Reset button until the rear panel Reset LED and the front panel View

and Esc buttons blink once (events reset), twice (system reset), or three times

(absolute reset).

RESET

Rx

RESET

RESET

RESET

Rx

RESET

RESET

RESET

Rx

RESET

RESET

I / O

RGBHV AUDIO

I / O

RGBHV AUDIO

I / O

RGBHV AUDIO

Front panel I/O buttons flash

once.

Front panel I/O buttons flash

twice.

Front panel I/O buttons flash

three times.

Press and

hold

the Reset button.

Release, then

immediately

press and release.

Release, then

immediately

press and release.

Release, then

immediately

press and release.

3 seconds

Events Reset

(Mode 3)

IP Settings

Reset

(Mode 4)

Reset LED
flashes

once.

1

Press and

hold

the Reset button.

6 seconds

Reset LED
flashes

twice.

2

Absolute

Reset

(Mode 5)

Press and

hold

the Reset button.

9 seconds

Reset LED
flashes

three

times.

3

Reset LED
flashes

four

times.

3

Reset LED
flashes

four

times.

3

Reset LED
flashes

four

times.

3

2

.

Release the Reset button and then immediately press and release the Reset

button again. Nothing happens if the second momentary press does not occur

within 1 second.