Rear panel operations – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 79

Advertising
background image

3-47

CrossPoint 450 Plus and MAV Plus Switchers • Operation

Rear Panel Operations

The rear panel has a Reset button that initiates four levels of resets (numbered 1, 3,

4, and 5 for the sake of comparison with an Extron IPL product). The Reset button

is recessed, so use a pointed stylus, ballpoint pen, or small screwdriver to access it.
See the following table for a summary of the modes.

C

Review the reset modes carefully. Using the wrong reset mode may result
in unintended loss of flash memory programming, port reassignment, or a
controller reboot.

N

The reset modes listed below close all open IP and Telnet connections and close

all sockets. Also, the following modes are separate functions, not a continuation
from mode 1 to mode 5.

Reset Mode Comparison/Summary

Mode

Activation

Result

Purpose/Notes

1

Hold down the recessed Reset button

while applying power to the switcher.

N

After a mode 1 reset is

performed, update the switcher’s
firmware to the latest version.

Do not operate the switcher
firmware version that results
from the mode 1 reset. If you
want to use the factory default
firmware, you must upload that
version again. See chapter 5,
“Matrix Software”,
for details
on uploading firmware.

The switcher reverts to the factory default
firmware.

Event scripting does not start if the

switcher is powered on in this mode. All user files

and settings, such as IP settings, are maintained.

N

If you do not want to update firmware, or

if you performed a mode 1 reset by mistake,
cycle power to the switcher to return to the
firmware version that was running before the
mode 1 reset. Use the 0Q SIS command to
confirm that the factory default firmware is
no longer running (look for the asterisk [*]
following the version number.

Use mode 1 to revert

to the factory default

firmware version if

incompatibility issues

arise with user-loaded

firmware.

3

Hold down the Reset button for about

3 seconds, until the Reset LED blinks

once, then press Reset momentarily

(<1 second) within 1 second.

Mode 3 turns events on or off.

During resetting,

the Reset LED flashes two times if events are

starting, three times if events are stopping.

Mode 3 is useful for

troubleshooting.

4

Hold down the Reset button for

about 6 seconds, until the Reset LED

blinks twice (once at 3 seconds and

again at 6 seconds). Then press Reset

momentarily (<1 second) within 1

second.

Mode 4:
• Enables ARP capability.

• Sets the IP address to the factory default.

• Sets the subnet address to the factory default.

• Sets the gateway address to the factory default.

• Sets port mapping to the factory default.

• Turns DHCP off.

• Turn events off.

The Reset LED flashes four times in quick

succession during the reset.

Mode 4 enables you

to set IP address

information using ARP

and the MAC address.

5

Hold down the Reset button for

about 9 seconds, until the Reset LED

blinks three times (once at 3 seconds,

again at 6 seconds, and then again

at 9 seconds). Then press Reset

momentarily (<1 second) within 1

second.

Mode 5 performs a complete reset to factory
defaults (with the exception of the firmware):
• Does everything mode 4 does.

• Resets most settings including:

Clears all ties and presets.

Clears all output mutes.

Clears all I/O grouping.

• Resets all IP options.

• Removes/clears all files for the switcher.

The reset LED flashes four times in quick

succession during the reset.

Mode 5 is useful if

you want to start over

with configuration and

uploading or to replace

events.

Same as

E

ZQQQ

}

SIS command,

see chapter 4,

“Programmer’s

Guide“.

For different reset levels, press and hold the button while the switcher is running or

press and hold the button while you apply power to the switcher.