CrossPoint 450 Plus and MAV Plus Switchers • Matrix Software

Hardware status

Provides an overall view of the status of the matrix switcher,

including the power supply voltages, the temperature status, the Remote

RS-232/RS-422 port configuration, and the installed and updated firmware

status (figure 5-16).

Green — Proper operation.
Red — Component has failed.
White — Component is not installed.

Figure 5-16 — Status window

Name presets

Allows you to assign a name to each of the 64 global memory

presets and 100 room presets.

N

Preset names are limited to 12 upper- and lower-case alphanumeric characters,

space, and the _ and / characters.

N

The following characters are invalid in preset names:

+ ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

Show RS-232 Strings

Displays the ASCII commands that are used by the

current configuration. You can refer to these for SIS programming.

I/O group settings

Allows you to establish I/O groups.

Room configuration

Allows you to assign outputs to rooms or delete outputs

from rooms.

N

A Room is a subset of outputs that are logically related to each other, as

determined by the operator. The matrix switcher supports up to 10 rooms, each
of which can consist of from 1 to 16 outputs.

Initialize

Initializes and clears any or all of the following: ties, presets, preset

names, icon names, and icons.