Command/response table for sis commands, Symbol definitions, Command/response.table.for.sis.commands -8 – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 96: Symbol.definitions -8, Programmer’s guide, cont’d

Advertising
background image

Programmer’s Guide, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

4-8

Command/response table for SIS commands

Symbol definitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D)

= Space character

E

= Escape key (hex 1B)

X!

= Input number (for tie)

00 – (maximum number of inputs for your model) (00 = untie)

X@

= Output number

00 – (maximum number of outputs for your model) (00 = untie)

X#

= Mute, Lock mode, power supply

0 = off/mode 0/not OK

1 = on/mode 1/OK

2 = mode 2

X$

= Input number

01 – (maximum number of inputs for your model)

X%

= Audio gain

00 – 24 (1 dB/step)

X^

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

X&

= Audio attenuation

1 – 18 (1 dB/step)

X*

= Volume adjustment range

0 – 64 (1 dB/step except for 0-to-1, which is 12.5 dB)

(see the table on page 4-11)

X(

= Global preset #

00 – 64 (0 = current configuration)

X1)

= Room # (for room presets)

01 – 10 max. (each can have up to 10 presets [

X1@

s] assigned)

N

A Room is a subset of operator-selected outputs that relate to each other. The switcher supports up to 10 rooms, each of which can consist

of from 1 to 16 outputs.

X1!

= Name

12 characters maximum for global, room preset, input, and output

names

11 characters maximum for room names

Upper- and lower-case alphanumeric characters and

_ : = / and spaces are valid.

N

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X1@

= Room preset #

01 – 10 maximum

N

A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,

it becomes the current configuration.

X1#

= Video/audio mute:

0 = no mutes

1 = video mute

2 = audio mute

3 = video and audio mute

X1$

= Sync frequency

xxx.xx (frequency in Hz [V] or kHz [H])

X1%

= Signal detection

0 = no input detected, 1 = input detected)

X1^

= RGB delay interval

Delay in ½ second increments (10 maximum)

X1&

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X1*

= BME type

1 = wideband video

2 = low resolution video

3 = Sync

4 = stereo audio

5 = mono audio

X1(

= # of connected BMEs in the system

1 through 6

X2)

= Firmware version number to second decimal place (x.xx)

X2!

= Verbose firmware version-description-upload date/time. See page 4-19.

X2@

= Voltage

Positive or negative voltage and magnitude

X2#

= Temperature

Degrees Fahrenheit

X2$

= Fan speed

RPM