Ethernet (lan) port, Ethernet connection, Default ip addresses – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 92: Ethernet (lan) port, Ethernet.connection -4 default.ip.addresses -4, Programmer’s guide, cont’d

Advertising
background image

Programmer’s Guide, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

4-4

Ethernet (LAN) Port

The rear panel Ethernet connector on the switcher can be connected to an Ethernet

LAN or WAN. Communication between the switcher and the controlling device is

via telnet (a TCP socket using port 23). The TCP port can be changed if necessary,

via SIS. This connection makes SIS control of the switcher possible using a

computer connected to the same LAN or WAN. The SIS commands and the actions

of the switcher are identical to the commands and actions the switcher has when

the computer is communicating with it via a serial port.

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover

cable and must be properly terminated for your application (figure 4-3).

Crossover cable — Direct connection between the computer and the

CrossPoint 450 Plus or MAV Plus switcher

Patch (straight-through) cable — CrossPoint 450 Plus or MAV Plus switcher

to an Ethernet LAN

A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.

A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Crossover Cable

Straight-through Cable

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

End 1

End 2

End 1

End 2

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

Pin

1

2
3
4
5
6
7
8

Wire color

White-orange

White-green

Blue

White-blue

White-brown

Brown

Wire color

T568B

T568B

White-orange

Orange

Orange

White-green

Blue

White-blue
Green

Green

White-brown

Brown

Figure 4-3 — RJ-45 Ethernet connector pin assignments

Default IP addresses

To access the CrossPoint 450 Plus or MAV Plus switcher via the LAN port, you need

the Extron IP address, and may need the subnet mask and the gateway address. If

the IP address has been changed to an address comprised of words and characters,

you can determine the actual numeric IP address using the ping (ICMP) utility

(see appendix A, “Ethernet Connection”, for more details). If the addresses have

not been changed, the factory-specified defaults are:

• IP address:

192.168.254.254

• Subnet mask:

255.255.0.0

• Gateway address: 0.0.0.0

• DHCP:

off