Connect the bme comm interconnecting cables, Installation, cont’d – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 26

Advertising
background image

Installation, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Installation

2-8

g

BME COMM interconnect ports —

If the matrix switcher system consists of

more than one BME, the BMEs must be connected together in a daisy chain

using Extron-supplied RJ-45 cables.
a

. Connect the first daisy chain from BME 0’s BME Comm Out connector to

the nearest BME’s BME Comm In connector (figure 2-9). In a rack where

BMEs are arranged so that their physical location matches the BME

address numbering, this would be BME 1. But since not all systems are

configured alike, call this module BME n.

64

63

62

61

LAN

ACT LINK

RESET

REMOTE

Rx

Tx

Rx

Tx

4

-

+

BME COMM

IN

OUT

BME

ADDRESS

EXT

SYNC

Rx

Tx

8

9 10

6

11

7

RESET

REMO

TE

Rx

Tx

Rx

Tx

LAN

ACT

LINK

64

63

62

61

BME COMM

OUT

IN

BM

E

ADD

RES

S

EXT

SYNC

4

From previous BME

To next BME

Figure 2-9 — Daisy-chaining BMEs (video BME shown)

b

. Connect the next RJ-45 cable from BME n’s BME Comm Out connector to

the nearest unconnected BME’s (BME n+1’s) BME Comm In connector.

c

. Continue connecting RJ-45 cables from each daisy-chained module’s BME

Comm Out connector to the next module’s BME Comm In connector

until all modules are included in the chain. When all of the BMEs are

connected, each of the BMEs in the system is connected to at least one

other BME via the BME Comm connectors.