Example 5: grouping inputs and outputs, Example.5:.grouping.inputs.and.outputs -25 – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 57

Advertising
background image

3-25

CrossPoint 450 Plus and MAV Plus Switchers • Operation

Example 5: Grouping inputs and outputs

In the following example, several switcher inputs and outputs are assigned to

groups. The steps show the front panel indications that result from your actions.

1

.

Clear all selections

: Press and release the Esc button.

C O N T R O L

PRESET

ENTER

ESC

VIEW

Press the Esc button to clear all selections.

The button flashes once.

2

.

Select

I/O Group mode

: Press and hold the Input 1 and Output 1 buttons for

approximately 2 seconds and then release the buttons.

1

1

17 18 19

1 2 3

I

N

17 18 19

1 2 3

O
U

T

Press and

hold the Input 1 button and Output 1 button.

Release the Input 1 button
and Output 1 button.

Ungrouped input and
output buttons light.

2 seconds

3

.

Select an I/O group

: Press and release the Enter button to select group 1.

C O N T R O L

PRESET

ENTER

ESC

VIEW

1

3

2

4

Press and release the Enter button to select group 1.
The button lights to indicate the selection.

Group #

4

.

Assign inputs and outputs

: Press and release the input 1 through 4 and

output 1 through 4 buttons.

17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8

25

9

I

N

17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8

25

9

O
U

T

Press and release the Input 1 through Input 4 buttons. The selected buttons light.

Press and release the Output 1 through Output 4 buttons. The selected buttons light.

Advertising