CrossPoint 450 Plus and MAV Plus Switchers • Installation

N

The length of exposed wires is critical. The ideal length is 3/16 inch (5 mm).

• If the stripped section of wire is longer than 3/16 inch, the exposed wires may

touch, causing a short circuit between them.

• If the stripped section of wire is shorter than 3/16 inch, wires can be easily

pulled out even if tightly fastened by the captive screws.

The volume level for each output can be individually set via the front panel or

via Ethernet or RS-232/RS-422 control. See chapter 3, "Operation", chapter 4,

"Programmer's Guide", chapter 5, "Matrix Software", and chapter 6, "HTML

Operation" for details.

BME connection and selection

N

BME 0 should house the front panel controller and be the BME used for system

control and monitoring via the serial ports and Ethernet LAN link.

f

BME address switch — To set the BME address, press the + and - buttons on

the BME Address switch on the rear panel of the switcher (figure 2-8).
• Each BME must be set to a unique address of 0 through 5.
• Addresses 6 through 9 are invalid.
• The addresses used in the system must be sequential with no skipped

numbers.

• Sync BMEs cannot be set to address 0.

64

63

62

61

LAN

ACT LINK

RESET

REMOTE

Rx

Tx

Rx

Tx

BME COMM

IN

OUT

EXT

SYNC

Rx

Tx

4

-

+

BME

ADDRESS

6

8

9 10

11

7

Tx

Rx

BME COMM

OUT

REMO

TE

Rx

Tx

LAN

ACT

LINK

EXT

SYNC

BM

E

ADD

RES

S

4

4

64

63

62

61

Figure 2-8 — Setting a BME address (video BME shown)

Advertising
This manual is related to the following products: