CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

Command/Response Table for IP-Specific SIS Commands

Symbol definitions

X3)

= Matrix name

(Up to 240 characters)

N

The following characters are invalid in the name: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ | and ?.

X3!

= Default name

Factory default name (model name + last 3 pairs of MAC address)

X3@

= Time and date (set)

In the format: MM/DD/YY•HH:MM:SS where:

MM = month: 01 (January) through 12 (December)

DD = day: 01 – 31

YY = year: 00 – 99

HH = hour: 00 – 24

MM = minutes: 00 – 59

SS = seconds: 00 – 59

X3#

= Time and date (read)

In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where

Day = weekday: Mon – Sun

DD = day: 01 – 31

Mmm = month: Jan – Dec

YYYY = year: 2000 – 2099

HH = hour: 00 – 24

MM = minutes: 00 – 59

SS = seconds: 00 – 59

X3$

= GMT offset

-12.0 through +14.0 (hours and minutes removed from GMT)

X3%

= Daylight Saving Time

0 = Daylight Saving Time off/ignore

1 = Daylight Saving Time on (northern hemisphere)

2 = Daylight Saving Time on (Europe)

3 = Daylight Saving Time on (Brazil)

X3^

= IP address

###-###-###-###

X3&

= Hardware (MAC) address

##-##-##-##-##-##

X3*

= Number of open connections

0 – 255

X3(

= Password

12 alphanumeric characters

N

The following characters are invalid in passwords: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ | and ?.

X4)

= Domain name

Standard domain name conventions apply (for example, xxx.com)

N

The following characters are invalid in passwords: {space} ~ , = ` [ ] { } < > ‘ “ ; : \ | and ?.

The @ character is only acceptable as the lead-in to the domain name (such as @extron.com).

X4!

= E-mail account

65 – 72. 65 = e-mail recipient #1, 66 = 2, 67 = 3, ... , 72 = recipient #8.

X4@

= E-mail address

Typical e-mail address format (for example: [email protected])

X4#

- Notify when?

0 = No response, 1 = fail/missing, 2 = fixed/restored, 3 = both 1 and 2

X4$

= Notification selections

01 – 64 = input numbers

98 = power supplies

99 = fans

X4%

= Notify status (for read)

66-digit number. For each digit: 0 = do not notify, 1 = notify.

X4^

= DHCP

0 = off, 1 = on

X4&

= Port #

01 = rear panel Remote port, 02 = front panel Configuration port)

X4*

= Baud rate

9600, 19200, 38400, 115200

X4(

= Parity

O

dd, even, none, mark, space (only first letter required)

X5)

= Data bits

7, 8

X5!

= Stop bits

1, 2

X5@

= Port type

0 = RS-232, 1 = RS-422

X5#

= Verbose mode

0 = Clear/none (default for Telnet connection

1 = Verbose mode (default for RS-232 / RS-422 connection)

2 = Tagged responses for queries

3 = Verbose mode and tagged for queries

N

If tagged responses is enabled, all read commands return the constant string and the value as the set command does (for example, the read

matrix name command,

E

CN

}

, returns IPN

X3)]

).

X5$

= Security level

00 = Anonymous

11 = User

10 = Extended security levels 1 through 10

12 = Administrator

X5%

= Port timeout interval (in 10-sec. increments)

1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)