Establishing a connection, Connection timeouts, Number of connections – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 93: Using verbose mode

Advertising
background image

4-5

CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide

Establishing a connection

Establish a network connection to a CrossPoint 450 Plus or MAV Plus switcher as

follows:

1

.

Open a TCP socket to port 23 using the switcher’s IP address.

N

If the local system administrators have not changed the value, the

factory-specified default, 192.168.254.254, is the correct value for this field.

The switcher responds with a copyright message that includes the copyright

year, product name, firmware version, part number, and the current date and

time.

N

If the switcher is not password-protected, the device is ready to accept SIS

commands immediately after it sends the copyright message.

N

If the switcher is password-protected, a

password prompt appears below the

copyright message.

2

.

If the switcher is password protected, enter the appropriate administrator or

user password.

If the password is accepted, the switcher responds with

Login User or

Login Administrator.

If the password is not accepted, the

Password prompt reappears.

Connection Timeouts

The LAN port times out after a designated period of time of no communications.

By default, this timeout value is set to 5 minutes but the value can be changed.

See the "Set current port timeout" SIS commands on page 4-23.

N

Extron recommends leaving the default timeout at 5 minutes and periodically

issuing the Query (Q) command to keep the connection active. If there are long
idle periods, Extron recommends disconnecting the socket and reopening the
connection when another command must be sent.

Number of connections

A CrossPoint 450 Plus or MAV Plus switcher can have up to 200 simultaneous

TCP connections, including all HTTP sockets and telnet connections. When the

connection limit is reached, the switcher accepts no new connections until some

have been closed.
No error message or indication is given that the connection limit has been reached.

To maximize performance of an IP Link device, keep the number of connections

low and close unnecessary open sockets.

Using Verbose Mode

Telnet connections to a CrossPoint 450 Plus or MAV Plus switcher can be used

to monitor for changes that occur on the switcher, such as front panel operations

and SIS commands from other telnet sockets or a serial port. For a telnet session

to receive change notices from the switcher, the telnet session must be in verbose

mode 3. See the "Set Verbose Mode" SIS command on page 4-23. In verbose

mode 3, the telnet socket reports changes in messages that resemble SIS command

responses.