Operation, cont’d – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 60

Advertising
background image

Operation, cont’d

CrossPoint 450 Plus and MAV Plus Switchers • Operation

3-28

2

.

Enter RGB Delay mode

: Press and hold the RGBHV button for

approximately 2 seconds until it blinks.

RGBHV

RGBHV

Press and hold the RGBHV
button until it blinks.

2 seconds

3

.

Select an output

: Press and release the Output 17 button.

17 18 19

1 2 3

O
U

T

17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8

25

9

26

10

27

11

I

N

Press and release the
Output 17 button.
The button lights.

The Input 1 through Input 10 buttons display the selected output's RGB delay.
Each lit input button indicates 0.5-second of delay.
In this example, the lit input buttons display 3.5 seconds of RGB delay.

3.5

3.0

2.5

2.0

1.5

1.0

0.5

N

The RGB delay is protected when front panel

lock mode 2 is selected. You

can view the delay in

lock mode 2, but not change it from the front panel. See

“Setting the front panel Locks (

Executive modes)” on page 3-43.

If front panel

lock mode 2 is selected and you try to perform step 4, the actions

are ignored and the Enter, RGBHV, and Audio buttons flash.

4

.

Increase the delay

: Press and release the Esc (

>

) button once to increase the

RGB delay by a half second.

Press and release the Esc (

>

) button twice more to increase the RGB delay by

a whole second. Note the input button indications that change each time the

Esc (

>

) button is pressed and released.

The figure below show the result of pressing the Esc (

>

) button a total of three

times.

ESC

ESC

ESC

17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8

25

9

26

10

27

11

I

N

3.5

4.0

4.5

5.0

3.0

2.5

2.0

1.5

1.0

0.5

Press the Esc button to increase the RGB interval that is applied to switches to
the selected output by a half second per button push.

The Input 1 through Input 10 buttons display the selected output's RGB delay.
Each lit input button indicates 0.5-second of delay.
In this example, the lit input buttons display 5.0 seconds of RGB interval.

N

You can press and hold the Esc (

>

) or View (

<

) button to ramp the delay up or

down to the high or low limit.