Setting the front panel locks (executive modes), Front panel, Locks – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 75: Setting the front panel locks ( executive modes), Selecting the rear panel remote, Port protocol and baud rate, Setting the front panel locks, Executive modes), F. see "setting, The front panel locks ( executive modes)

Advertising
background image

3-43

CrossPoint 450 Plus and MAV Plus Switchers • Operation

Setting the front panel locks (Executive modes)

N

In a system with multiple front panel controllers, Extron recommends locking

(setting

Lock mode 1) the front panel of BMEs other than BME 0 to prevent

confusion.

The front panel security lockout limits the operation of the switcher system from

the front panel controller. When the switcher is locked, all of the front panel

functions are disabled except for the View-Only mode functions (see "Viewing a

configuration" on page 3-20). Other than in View-Only mode, if the user pushes a

front panel button when the switcher is locked, the RGBHV (CrossPoint 450 Plus)

or Video (MAV Plus) button and the Audio button flash twice and return to their

previous state.

Lock mode 0 — The front panel is completely unlocked. All front panel

functions are available.

Lock mode 1 — All changes are locked from the front panel (except for

setting Lock mode 2). Some functions can be viewed.

Lock mode 2 — Basic functions are unlocked. Advanced features are locked

and can be viewed only.

Basic features consist of:

Making ties

Saving and recalling presets

Setting input audio gain and attenuation

Changing Lock modes

Advanced features consist of:

Creating I/O groups

Setting RGB delay

Setting video and audio output mutes

Setting audio output volume

Setting the rear panel RS-232/RS-422 port protocol and baud rate

N

The switcher is shipped from the factory in

Lock mode 2.

Selecting Lock mode 2 or toggling between mode 2 and mode 0

N

If the switcher is in

Lock mode 0 or mode 1, this procedure selects mode 2.

If the switcher is in

Lock mode 2, this procedure selects mode 0 (unlocks the

switcher).

Change the Lock mode as shown:

I / O

VIDEO AUDIO

ENTER

I / O

VIDEO

AUDIO

ENTER

Press and

hold the Enter, RGBHV or Video, and Audio

buttons simultaneously to turn on Lock mode 2 or to
toggle between mode 2 and mode 0.

2 seconds

The Enter, RGBHV or Video,
and Audio buttons blink
twice to indicate the mode
change.
Release the buttons.