Software operation via ethernet, Ethernet protocol settings, Software.operation.via.ethernet -3 – Extron Electronics MAV Plus series Large Scale User Guide User Manual

Page 115: Ethernet.protocol.settings -3

Advertising
background image

5-3

CrossPoint 450 Plus and MAV Plus Switchers • Matrix Software

3

.

Scroll to the desired program and click Install (figure 5-2).

Figure 5-2 — Software installation

4

.

Follow the on-screen instructions. By default, the installation of the Matrix

Switchers Control Program creates a C:\Program Files\Extron\Matrix_

Switchers directory, and it places the following four icons into a group folder

named “Extron Electronics\Matrix Switchers”:

MATRIX Switcher+ Control Program

MATRIX Switcher+ Help

Uninstall MATRIX Switcher

Check for Matrix Updates

N

Besides the LAN port, the CrossPoint or MAV switcher can support remote

control via either the rear panel Remote RS-232/RS-422 port or the front panel
Configuration port (matrix sizes up to 1616).

Remote RS-232/RS-422 port — The port can be configured for either the
RS-232 or RS-422 serial communication protocol and operate at 9600, 19200,
38400, or 115200 baud. See “Selecting the rear panel Remote port protocol and
baud rate”
in chapter 3, “Operation”, to configure the rear panel port from the
front panel.

Configuration port (matrix sizes up to 1616 only) — The port supports
RS-232 serial communication protocol only. The port can operate at 9600,
19200, 38400, or 115200 baud, but Extron recommends leaving this port

at 9600 baud. See the Set serial port parameters commands on page 4-23 to
configure either port using an SIS command.

Software operation via Ethernet

When a matrix switcher BME is connected to an Ethernet WAN or LAN, up to

200 users can operate it, locally or remotely, using the Matrix Switchers Control

Program. See “Ethernet” in chapter 2, “Installation”, for installation details.
Connection to the switcher BME via the Ethernet is password protected. There

are two levels of password protection: administrator and user. Administrators

have full access to all switching capabilities and editing functions. Users can select

inputs and outputs, set and recall presets, and view all settings with the exception

of passwords. If the same password or no password is required for logging on, all

personnel log on with administrator privileges. Fields and functions that exceed

user privileges are not selectable in the Matrix Switchers Control Program when the

operator is logged on as a user.

Ethernet protocol settings

The IP Settings/Options window (figure 5-7 on page 5-8) provides a location for

viewing and, if connected via the RS-232 link or if logged on via the Ethernet

port as an administrator, editing settings unique to the Ethernet interface. See

“IP Settings/Options window” later in this chapter for more details.