RUNNING THE BELTPACK UPGRADER

To use the beltpack upgrader connect the beltpack serial cable to the
COM port of the PC and the beltpack to be upgraded and switch the
beltpack on. Run the beltpack upgrader program and click on the ‘...’
button to navigate to the required firmware file (.mot). The COM port
can be set by opening the ‘File’ menu and clicking on the ‘COM Port’
entry. Select the COM port from the drop-down list.

Figure 11-17: Beltpack Upgrader Startup

Once the firmware file has been selected click on the ‘Download’
button to start the upgrade. A progress bar will be displayed as the
beltpack upgrade is carried out. The beltpack screen will display a
message to indicate that the upgrade is in progress.

Figure 11-18: Beltpack Upgrade Progress

When the beltpack upgrade is complete the upgrade program can be
closed and the cable unplugged. The beltpack is now ready for use.