Syslog messages – Brocade BigIron RX Series Configuration Guide User Manual

Page 1467

Advertising
background image

BigIron RX Series Configuration Guide

1389

53-1002484-04

Syslog messages

A

Syslog messages

Table 242

lists all of the Syslog messages. The messages are listed by message level, in the

following order:

Emergencies (none)

Alerts

Critical

Errors

Warnings

Notifications

Informational

Debugging

TABLE 242

Brocade Syslog messages

Message level

Message

Explanation

Alert

Power supply

<

num>,

<

location>, failed

A power supply has failed.
The

<

num> is the power supply number.

The

<

location> describes where the failed

power supply is in the device.

Alert

Fan

<

num>,

<

location>, failed

A fan has failed.
The

<

num> is the power supply number.

The

<

location> describes where the failed

power supply is in the device.

Alert

Management module at slot

<

slot-num>

state changed from

<

module-state> to

<

module-state>.

Indicates a state change in a management
module.
The

<

slot-num> indicates the device slot

containing the module.
The

<

module-state> can be one of the

following:

active

standby

crashed

coming-up

unknown

Alert

Temperature

<

degrees> C degrees, warning

level

<

warn-degrees> C degrees, shutdown

level

<

shutdown-degrees> C degrees

Indicates an overtemperature condition on
the active module.
The

<

degrees> value indicates the

temperature of the module.
The

<

warn-degrees> value is the warning

threshold temperature configured for the
module.
The

<

shutdown-degrees> value is the

shutdown temperature configured for the
module.

Alert

<

num-modules> modules and 1 power

supply, need more power supply!!

Indicates that the device needs more power
supplies to run the modules in the device.
The

<

num-modules> parameter indicates the

number of modules in the device.

Alert

OSPF Memory Overflow

OSPF has run out of memory.

Advertising