Lldp statistics – Brocade BigIron RX Series Configuration Guide User Manual

Page 353

Advertising
background image

BigIron RX Series Configuration Guide

275

53-1002484-04

Configuring LLDP

9

The following shows an example report.

Syntax: show lldp

The following table describes the information displayed by the show lldp statistics command.

LLDP statistics

The show lldp statistics command displays an overview of LLDP neighbor detection on the device,
as well as packet counters and protocol statistics. The statistics are displayed on a global and
per-port basis.

The following shows an example report.

This field...

Displays...

LLDP transmit interval

The number of seconds between regular LLDP packet transmissions.

LLDP transmit hold
multiplier

The multiplier used to compute the actual time-to-live (TTL) value of an LLDP
advertisement. The TTL value is the transmit interval multiplied by the transmit hold
multiplier.

LLDP transmit delay

The number of seconds the LLDP agent will wait after transmitting an LLDP frame and
before transmitting another LLDP frame.

LLDP reinitialize delay

The minimum number of seconds the device will wait from when LLDP is disabled on a
port, until a request to re-enable LLDP on that port will be honored.

LLDP maximum
neighbors

The maximum number of LLDP neighbors for which LLDP data will be retained, per
device.

LLDP maximum
neighbors per port

The maximum number of LLDP neighbors for which LLDP data will be retained, per port.

BigIron RX#show lldp

LLDP transmit interval : 10 seconds

LLDP transmit hold multiplier : 4 (transmit TTL: 40 seconds)

LLDP transmit delay : 1 seconds

LLDP SNMP notification interval : 5 seconds

LLDP reinitialize delay : 1 seconds

LLDP maximum neighbors : 392

LLDP maximum neighbors per port : 4