Syslog messages, Web management, Configuring lldp – Brocade BigIron RX Series Configuration Guide User Manual

Page 338: Configuration notes and considerations

Advertising
background image

260

BigIron RX Series Configuration Guide

53-1002484-04

Syslog messages

9

Syslog messages

Syslog messages for LLDP provide management applications with information related to MIB data
consistency and general status. These Syslog messages correspond to the lldpRemTablesChange
SNMP notifications.

Web Management

Web Management Interface is not supported.

Configuring LLDP

This section describes how to enable and configure LLDP.

Table 64

lists the LLDP global-level tasks and the default behavior/value for each task.

Configuration notes and considerations

LLDP is supported on Ethernet interfaces only.

If a port is 802.1X-enabled, the transmission and reception of LLDP packets will only take
place while the port is authorized.

TABLE 64

LLDP global configuration tasks and default behavior / value

Global task

Default behavior / value when LLDP is enabled

Enabling LLDP on a global basis

Disabled

Specifying the maximum number of LLDP
neighbors per device

Automatically set to 392 neighbors per device

Specifying the maximum number of LLDP
neighbors per port

Automatically set to 4 neighbors per port

Enabling SNMP notifications and Syslog messages

Disabled

Changing the minimum time between SNMP traps
and Syslog messages

Automatically set to 2 seconds when SNMP notifications and
Syslog messages for LLDP are enabled

Enabling and disabling TLV advertisements

When LLDP transmit is enabled, by default, the Brocade
device will automatically advertise LLDP capabilities, except
for the system description, VLAN name, and power-via-MDI
information, which may be configured by the system
administrator.
Also, if desired, you can disable the advertisement of
individual TLVs.

Changing the minimum time between LLDP
transmissions

Automatically set to 2 seconds

Changing the interval between regular LLDP
transmissions

Automatically set to 30 seconds

Changing the holdtime multiplier for transmit TTL

Automatically set to 4

Changing the minimum time between port
reinitializations

Automatically set to 2 seconds

Advertising