General flow parameter rules, General flow parameter rules 3, Flow – Brocade Network Advisor SAN User Manual v12.1.0 User Manual

Page 1090: Parameter and configuration rules and limitations

Advertising
background image

Brocade Network Advisor SAN User Manual

1043

53-1002948-01

Flow parameter and configuration rules and limitations

30

Flow parameter and configuration rules and limitations

Parameters and values for configuring flows may only be supported on specific switch platforms
and when enabling specific Flow Vision applications, such as Flow Generator, Flow Mirror, and Flow
Monitor.

General flow parameter rules

Following are general rules for provisioning flows in the Add Flow Definition dialog box. Note that
noncompliance will cause error messages.

Use unique names for flows defined in a physical switch. Names do not have to be unique for
flows defined in logical switches.

Changing between Port Address (PID) and WWN format for source and destination end
devices. This may cause an error if WWN to PID cannot be resolved.

Source and destination device identifiers must be in the same format - either WWN or Port
Address.

Ingress and egress port identifiers cannot be provided in the same flow.

Flow definitions are only supported on Flow Vision capable switches. Refer to

“Supported

parameters by platform and switch configuration mode”

on page 1041 for information on

supported platforms.

Use unique flow definitions. Duplicate flow definitions are not allowed.

TABLE 93

Flow definition based on context where Add Flow Definition dialog box launched

Context

Flow Created

Definition parameters in dialog box

Switch port

Flow definition created to monitor the traffic on
the selected port without inferring with
connected device

Ingress switch port = <port>
Source device = *
Destination device = *
Features = Monitor

Switch port

Flow definition created to monitor the traffic on
the selected port while inferring connected
device.

Ingress switch port = <port>
Source device = <device PID>
Destination device = *
Features = Monitor

Initiator port

Flow definition created on the switch attached
to the initiator port.

Ingress switch port = <port>
Source Device = <device PID>
Destination Device = *
Features = Monitor

Target port

Flow definition created on the switch attached
to the target port.

Ingress switch port = <port>
Source Device = <device PID>
Destination Device = *
Features = Monitor

Switch

Flow definition created on the selected switch.

Source device = *
Destination device = *
Features = Monitor