Adding a policy monitor

32

c. If you selected the Check for redundant connections to neighboring switches (SAN only)

check, enter the minimum number of connections allowed between a switch pair in the
Minimum Connections field.

The default recommended is 2. Valid values are from 2 through 512.

d. Select the switches or routers to which you want to apply this policy in the Available

Switches/Routers list and click the right arrow button.

NOTE

You can use the All SAN Switches targets (under the Product Groups > System Product
Groups node) in the Available Switches/Routers list) for future provisioning. Select All SAN
Switches and click the right arrow button to apply this policy to all discovered switches.

The selected switches display in the Selected Switches/Routers list.

8. To set policy monitors for hosts, select the Host Checks tab (

Figure 449

) and complete the

following steps.

FIGURE 449

Add Policy Monitor dialog box, Hosts Checks tab

a. Select the Check for redundant connections to attached fabrics check box to determine if

there are at least the minimum number of configured physical connections between the
host and the attached fabric.

The default is 2. For more information about this check and a fix for rule violations, refer to

“Host policy monitors”

on page 1065.

b. Enter the minimum number of connections between the host and the attached fabric in

the Minimum Connections field.

The default is 2.