Flow monitor supported flow parameter combinations – Brocade Network Advisor SAN User Manual v12.1.0 User Manual

Page 1092

Advertising
background image

Brocade Network Advisor SAN User Manual

1045

53-1002948-01

Flow parameter and configuration rules and limitations

30

The destination device and egress port indicate the destination of the test traffic. For Flow
Generator, these should be the same port.

The source is on the local switch, but the destination can be local or remote.

Bidirectional, and the advanced flow identification parameters (LUN IDs or Frame Type) are not
supported for Flow Generator.

Entering an asterisk for a flow identifier value causes Flow Generator to use all values for that
identifier. For example, if a specific WWN is used for the source device, and an asterisk is specified
for the destination device, Flow Generator will create flows from the source device WWN to all
destination device WWNs that are in the same zone as the source device.

Flow Mirror supported flow identification parameter combinations

Table 95

lists the supported flow parameter combinations for Flow Mirror.

Flow Monitor supported flow parameter combinations

Table 96

lists the supported flow parameter combinations for Flow Monitor.

NOTE

In the following combinations, an asterisk (*) is also supported as source and destination device
values for learning flows only on 16 Gbps-capable Fibre Channel platforms.

TABLE 95

Advanced Flow ID parameter combinations for Flow Mirror

Source
Device

Destination
Device

Ingress Port

Egress Port

Bidirectional

LUN IDs

Frame Type

Description/ Notes

Fixed value,
Not specified,
or Any (*)

Fixed value,
Not specified,
or Any (*)

Not specified Fixed value

Not specified

Fixed value or
Not specified

Fixed value

Frame Type and
Bidirectional cannot be
supported together

Fixed value,
Not specified,
or Any (*)

Fixed value,
Not specified,
or Any (*)

Not specified Fixed value

Fixed value or
Not specified

Fixed value or
Not specified

Not specified At least one frame

parameter should be
specified in the flow.

Fixed value,
Not specified,
or Any (*)

Fixed value,
Not specified
or Any (*)

Fixed value

Not specified Fixed value or

Not specified

Fixed value or
Not specified

Not specified Ingress port and Frame

Type cannot be supported
together

TABLE 96

Flow parameter combinations for Flow Monitor

Source
Device

Destination
Device

Ingress Port

Egress Port

LUN IDs

Frame Type

Bidirectional

Description/ Notes

Fixed value or
Not specified

Fixed value or
Not specified

Fixed value

Not specified Not specified

Not specified Fixed value

Bidirectional is not
supported with LUN IDs or
Frame Type values

Fixed value or
Not specified

Fixed value or
Not specified

Not specified Fixed value

Not specified

Not specified Fixed value

Advertising