Examples of circuit failover in groups – Brocade Network Advisor SAN User Manual v12.1.0 User Manual

Page 864

Advertising
background image

816

Brocade Network Advisor SAN User Manual

53-1002948-01

FCIP trunking

22

Consider available WAN bandwidth requirements when configuring failover circuit groups.
Refer to

“Bandwidth calculation during failover”

on page 814.

Examples of circuit failover in groups

Tables

Table 68

through

Table 70

provide examples of how failover occurs on circuits with different

bandwidths configured in failover groups.

Table 68

illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All

data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:

If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.

If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.

If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.

Table 69

illustrates circuit failover in a tunnel with one failover group containing three circuits, In

this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.

Table 70

illustrates circuit failover in a tunnel with circuits in failover groups and circuits that are

not part of failover groups. In this configuration, all data is initially load balanced over circuit.1,
circuit 2, and circuit 3 (when they are all active). The following occurs during circuit failover:

If circuit1 fails, circuit 4 becomes active and data is load balanced over circuit 2, circuit 3, and
circuit 4.

Reason: Circuit 1 fails over to circuit 4 (both are in failover group 1) and circuit 3 is active with
500Mb bandwidth.

TABLE 68

Tunnel with two failover groups with two circuits

Circuits in tunnel

Failover group ID

Circuit bandwidth

In use for tunnel data

Circuit 1
Metric 0

1

500Mb

If active, yes.

Circuit 2
Metric 0

2

1000Mb

If active, yes.

Circuit 3
Metric 1

1

500Mb

Only when circuit 1
fails.

Circuit 4
Metric 1

2

1000Mb

Only when circuit 2
fails.

TABLE 69

Tunnel with one failover groups with three circuits

Circuits in tunnel

Failover group ID

Circuit bandwidth

In use for tunnel data

Circuit 1
Metric 0

1

1000Mb

If active, yes.

Circuit 2
Metric 1

1

500Mb

Only when circuit 1
fails.

Circuit 3
Metric 1

1

500Mb

Only when circuit 1
fails.

Advertising