Brocade Network Advisor SAN User Manual v12.1.0 User Manual

Page 1127

Advertising
background image

1080

Brocade Network Advisor SAN User Manual

53-1002948-01

Viewing a policy monitor report

32

Switch Checks include the following options:

Switch — Check for at least Configured_Minimum_Value connections to neighboring
switches. This check provides the following additional detail for this check:

-

Neighboring Switch — Name of the neighboring switch.

-

Connection Count — Number of connections to the neighboring switch.

Switch — Check for HTTPS (secure HTTP) configuration. This check provides the
following additional detail for this check:

-

HTTPs Status — Whether HTTPS is enabled or disabled on the product.

-

HTTP Status — Whether HTTP is enabled or disabled on the product.

Switch — Check if the product is configured to send events to this server.

Switch — Check if the product is configured to send Upload Failure Data Capture to an
FTP server.

Switch - Check for SSH (secure Telnet) configuration.This check provides the following
additional detail for this check:

-

SSH Status — Whether SSH is enabled or disabled on the product.

-

Telnet Status — Whether Telnet is enabled or disabled on the product.

Switch - Check for SNMPv3 (secure SNMP) configuration. This check provides the
following additional detail for this check:

-

SNMPv3 Status — Whether SNMPv3 is enabled or disabled on the product.

-

SNMP Status — Whether SNMP is enabled or disabled on the product.

Configuration Rule Checks — Switch checks provide the following information for each
selected check:

-

Block/Condition Name — Name of the block or condition.

-

Matched Block — Name of the matched block.

-

Status — Whether the configurations matched (Passed) or did not match (Failed).

-

Failed Condition — Name of the failed condition.

-

Match/Not Match — Whether the configurations matched (Match) or did not
match (Not Match).

-

Condition Details — Details about the condition.

-

Remediation — Details how to correct the failure, if the condition fails.

Host Checks — Switch checks provide the following information for each selected check:

Name — Product name.

Status — Result of the check and reason for failure if known. Valid results include
Passed, Partially Failed, Failed, Not Applicable, and Unknown.

Displays the Host name and status of the policy check for the following option:

Host — Check for at least Configured_Minimum_Value connections to attached fabrics

Host — Check for connections through two fabrics to each target LUN. This check
provides the following additional detail for this check:

-

LUN Serial # — LUN serial number.

-

Adaptor Port — Host adapter port number.

-

Fabric — Fabric name.